Auxiliary Power for Fast Chargers and Industrial Equipment: Comparing Chinese Depletion-MOSFET and Integrated Solutions
A controller needs power before a fast charger can begin switching. Industrial sensors and transmitters likewise need a stable low-voltage supply. These auxiliary circuits handle relatively little power, yet startup behaviour, losses and temperature can determine whether the wider system operates reliably.
The Chinese article's visit to the 23rd China Semiconductor Expo provides the setting for a closer look at depletion-mode MOSFETs and related products. Chengdu ARK Microelectronics supplies devices for high-voltage startup, linear auxiliary power and protection. Chipown and Kiwi Instruments are developing integrated approaches, while Oriental Semiconductor has disclosed work on a high-voltage auxiliary-power platform. For international designers assessing these suppliers, the first distinction is the function each product actually performs.

Exhibition photograph: the 23rd China Semiconductor Expo. The photograph establishes the event setting, not the adoption of any component discussed below.
ARK's portfolio extends beyond discrete depletion-mode devices
ARK's catalogue includes depletion-mode MOSFETs, high-voltage integrated regulators, overvoltage/overcurrent protection products, optical relays and enhancement-mode MOSFETs. Its activities encompass power and circuit protection; describing it solely as a depletion-mode discrete-device supplier would omit part of the portfolio.
An N-channel depletion-mode MOSFET conducts at zero gate-to-source voltage and turns off when a sufficiently negative gate-to-source voltage is applied. This allows a path to conduct before the controller receives power. Enhancement-mode MOSFETs have a different default state, so similar packages and voltage ratings do not establish interchangeability.
The device alone does not implement every regulation or protection function. Its location, gate connection and surrounding components determine whether it provides startup current, current limiting or linear power. ARK's application materials address these specific uses.
The catalogue's high-voltage integrated regulators, or HVIR products, add regulation control and temperature compensation. The illustrated applications include non-isolated regulation and overvoltage protection. Integration reduces the circuitry that customers must build around an individual MOSFET, while selection still depends on load and input conditions.

Figure 1. Original ARK catalogue excerpt, PDF page 14, printed page 13. The left circuit illustrates non-isolated regulation; the right illustrates overvoltage protection. The Chinese heading and text describe these two uses. Device-specific capabilities require the corresponding specifications.
ARK itself therefore offers both discrete and integrated products. Comparisons with power-management IC suppliers need to address a specific circuit rather than divide manufacturers into two fixed camps.
Startup and continuous controller power impose different requirements
ARK's March 2026 fast-charging circuit places DMZ6012E in the high-voltage startup branch and DMZ1015E in the PWM controller's auxiliary supply. The manufacturer describes them as a 600 V depletion-mode MOSFET and a 100 V ultra-high-threshold depletion-mode MOSFET, respectively. Their ratings reflect different circuit positions rather than a simple performance hierarchy.

Figure 2. ARK's application circuit published on March 19, 2026. The original red boxes identify startup and auxiliary-supply devices. This is a manufacturer circuit example.
At power-up, the startup branch charges the controller's supply capacitor. Once switching begins and another supply path is established, startup current can be reduced or disconnected. Slow charging delays startup, while continued current draw during normal operation adds losses. The depletion-mode device provides initial conduction; subsequent behaviour depends on the rest of the circuit.
Continuous power introduces different constraints. Fast-charger output-voltage changes can alter the auxiliary-winding voltage, but the controller supply must remain within its operating limits. Load steps and recovery from an output short circuit also test this branch. A single steady-state operating point does not represent all these conditions.
Startup selection emphasizes voltage withstand, charging time and losses after the branch exits. Continuous supply emphasizes output voltage, current and temperature. A high threshold voltage should not be interpreted as a guarantee of output-voltage accuracy.
External devices allow a supply branch to be adjusted while retaining an existing controller and transformer. If the controller already integrates startup or self-supply functions, the need for those devices should be reassessed against the design being retained.
Industrial low-current supplies remain limited by dissipation
ARK's February 2026 sensor/transmitter material lists DMZ42C10S, DMX1072 and DMX4022E as options. Devices between a higher-voltage input and low-voltage circuitry work with downstream regulation to power circuits such as DACs and contribute protection. The catalogue also shows a front-end device working with an LDO.

Figure 3. ARK's sensor/transmitter application circuits published on February 27, 2026. The part numbers are manufacturer-listed alternatives within the illustrated schemes.
A front-end device can absorb part of the voltage difference or provide protection while the downstream circuit continues regulating. This may preserve an existing low-voltage design. It does not increase the LDO's own absolute maximum ratings; the voltage reaching that LDO during abnormal input conditions still needs verification.
Linear power can be simple, but voltage drop produces heat. In a hypothetical 48 V-to-12 V path carrying 10 mA, voltage drop multiplied by current gives approximately 0.36 W of dissipation. At 50 mA, it becomes 1.8 W. These are principle-based calculations, not measurements of the illustrated circuits or a particular component.
An increase of only tens of milliamps can consequently change cooling requirements. A startup branch can reduce current after completing its task; a continuous supply cannot. Adequate voltage rating alone does not establish safe operation at every voltage/current combination. Safe operating area, package thermal performance and ambient temperature remain relevant.
HVIR integration does not remove these constraints. Simple linear circuits can be attractive for small currents and restricted board area. As continuous output power rises, switching conversion becomes more valuable. The boundary requires actual loss calculations and system requirements.
Integrated alternatives cover different functions and commercialization stages
Chipown's May 2026 material describes PN8703, a flyback converter for an 800 V bus. It integrates a 2000 V high-voltage startup circuit and a 1700 V SiC power device, eliminating an external startup resistor. The bus voltage and the ratings of these two internal functions must not be treated as one interchangeable specification.
PN8703 participates in an entire switching-converter stage, beyond a local supply branch. Transformer design, output rectification, feedback and electromagnetic interference remain part of the customer's work. Chipown's interim report separately states that products including 1700 V SiC auxiliary supplies for 800 V HVDC systems entered volume production. The application information describes functionality; the report provides commercialization evidence.
Kiwi Instruments' electronica China 2026 material places the KP220X auxiliary-power series in photovoltaic inverters, storage converters and charging modules. That equipment-level positioning does not make an entire series a substitute for one depletion-mode MOSFET.
Kiwi's interim report provides a separate technical disclosure: combining startup and supply circuits in primary-side regulation without an auxiliary winding to achieve low-loss charging. Primary-side regulation obtains regulation information from the transformer's primary side; the disclosed work addresses the controller's own supply. Removing an auxiliary winding can change transformer and peripheral arrangements, while shifting attention to the controller's input range and supply behaviour during load changes. This disclosure and the KP220X exhibition material do not prove that every KP220X product uses the same architecture.
Oriental Semiconductor remains a development-stage comparison. Its first-half report says the core architecture and layout of a high-voltage auxiliary-power IC platform were complete, with initial tape-out verification being advanced. An October convertible-bond prospectus draft also lists auxiliary-power ICs for 800 V high-voltage systems among proposed R&D products. Design completion, silicon verification and stable volume supply are distinct stages; these disclosures do not establish a mature, volume-procurable offering.

Figure 4. Functions and disclosed stages of four Chinese suppliers. Based on ARK's catalogue, 2026 manufacturer materials and interim reports, and Oriental Semiconductor's October filing draft. The comparison includes devices, integrated solutions and development platforms.
ARK's examples emphasize local power, current limiting and protection; Chipown's cited solution covers high-voltage auxiliary conversion; Kiwi connects auxiliary power with control architecture; Oriental Semiconductor still requires follow-through on validation and production. These approaches may compete in a new design or perform different tasks within the same equipment.
Selection economics extend to the whole board
Discrete devices can preserve an established design when only startup or local power needs improvement. HVIR products may simplify local regulation. Integrated control and power devices have greater scope when the whole auxiliary converter is being redesigned.
Purchase price is only one component of cost. Additional devices consume area and require coordination tests. A different controller may reduce external parts but require transformer changes, protection tuning and renewed debugging. An existing production board and a new project can therefore favour different choices from the same candidates.
Fast-charger evaluation should combine startup time, standby loss and controller supply during output switching. Industrial branches that run continuously require temperature, abnormal-input and load-change testing. A power-loss or voltage-rating figure without its operating conditions is insufficient for selection.
The useful comparison begins with the branch's job, then considers component count, losses, debugging and supply conditions. That establishes whether a discrete device, local integrated regulator or complete converter solution suits the board being designed.
This article summarizes public information for industry discussion. Product specifications, availability and suitability remain subject to current manufacturer documentation and application validation.